Deckma Omd11 Manual ((install)) Now
Verify the "Zero" reading using clean water; if the display does not show "0", re-adjust the offset in programming mode.
Generally 110/220V AC or 24V DC/AC depending on the configuration.
The manual's first operational section is commissioning. Before startup, the manual instructs technicians to perform rigorous checks: verifying that the is correctly connected, ensuring proper grounding (PE) is made per regulations, and checking all piping connections for leaks. For units with an automatic cell cleaning unit, the manual specifies that the air supply must be regulated to between 4 and 6 bar. Once these checks are complete, the OMD-11 is ready for its start-up sequence.
To program these, the operator uses a chord-press method: enters the programming mode. The display toggles between the letter "A" (Alarm setpoint) and a number, or "T" (Time delay) and a number. The setpoint or delay is adjusted using the arrow keys and confirmed by pressing the ■ button.
is its ability to distinguish between actual oil particles and solids or water turbidity. This significantly reduces false alarms caused by non-oil contaminants like black iron oxide. deckma omd11 manual
This public link is valid for 7 days and shares a thread, including any personal information you added. This link or copies made by others cannot be deleted. If you share with third parties, their policies apply. Can’t copy the link right now. Try again later.
If you are dealing with a specific error code or operational failure on your unit, tell me: What are currently showing on the front panel?
The distance between the monitor and the separator should never exceed 8 meters , ensuring the response time remains below 20 seconds as per IMO regulations.
Flush the measuring cell thoroughly with clean, oil-free fresh water. The display should stabilize and read . Verify the "Zero" reading using clean water; if
Regular cleaning of the measuring cell is essential to prevent solids from obstructing the optical sensor. Troubleshooting:
The is a fixed-type oil content monitor designed for use on board vessels to monitor the oil content of bilge water, ballast water, or oily mixtures. It is most commonly integrated into Oily Water Separators (OWS) (such as those manufactured by Sunny Maritime or similar) to ensure that discharged water meets international regulatory limits (typically 15 ppm or 100 ppm).
A near-infrared light source passes through the sample water.
Move the brush vertically up and down carefully to scrub away oil films, rust, or biological scaling. Before startup, the manual instructs technicians to perform
Remember: The OMD-11 is a life-saving device. The manual is not a paperweight; it is your legal defense in an incident investigation and your technical roadmap to keeping the crankcase safe. Print two copies: one for the engine control room and one for the technical superintendent’s office. Then, schedule a calibration check according to Section 6.4 – your crew and your engine will thank you.
Allow the display to stabilize. The reading should be 0 ppm (±2 ppm).
is a light-scattering oil-in-water monitor designed to meet IMO MEPC.60(33) regulations for 15 ppm oily water separators.